Pharmaceutical segment
Pest Control for Sterile Injectable & Ophthalmic Plants
Zero chemicals in Grade A/B — drains, airlocks and the building envelope, written into your CCS.
How we protect sterile and ophthalmic plants
In a sterile plant, pest control is part of contamination control. EU-GMP Annex 1 has no clause called "pest control" — it sits inside your contamination control strategy, next to premises, maintenance and the service providers you rely on. Our sterile programme keeps every chemical out of classified areas and stops pests where they actually get in: drains, airlocks, material transfer and gaps in the building.
Where pests reach a sterile plant
Sterile rules do not name pests much — they name the routes pests use. That is where an inspector looks, and where we work.
Grade A/B
No sinks or drains allowed
Annex 1 (4.9) and Schedule M Part II (8.6) ban drains in Grade A/B. In lower grades, trapped drains are a route that must be watched.
Annex 1 · 2.5
Contamination control strategy
Lists premises, maintenance and critical service providers. Your pest vendor belongs here — qualified, audited and under change control.
4.10
Material transfer
Annex 1 calls transfer into cleanrooms one of the greatest potential sources of contamination. Insects travel in on pallets and cartons.
What USFDA finds at Indian sterile sites
- A facility "in a state of disrepair", with gaps around HEPA filters and peeling ceiling paint (sterile ophthalmic site, Maharashtra — warning letter, 2024).
- Ceiling leaks near an aseptic filling line (sterile injectables site, Telangana — warning letter, 2024).
Source: public USFDA warning letters. We found no public pest finding inside an Indian sterile area — the findings are about the building. Gaps, leaks and decay are how pests get in, so that is where our programme starts.
Pests we target in sterile and ophthalmic plants
Drain flies
Grade C/D drains and floor channels
Cockroaches
Drains, utility corridors, service voids
Ants
Wall gaps and service penetrations
Rodents
Service floors, ceiling voids, perimeter
Birds
Roofs and AHU intakes
What the auditor asks for — and what you hand over
Every GMP standard asks for the same proof. This is how our programme answers each requirement.
| Requirement | Where auditors look for it | What IPCC gives you |
|---|---|---|
| Pest control inside your contamination control strategy | Source: EU-GMP Annex 1 (2022), 2.5 | Vendor qualification pack: SOP, method statements, training records and a change-control trail. |
| Nothing used for pest control may touch or contaminate product | Source: Schedule M Part I 14.3 and 16.5 | Zero chemicals in Grade A/B; monitoring only in Grade C; chemical control limited to Grade D and outside. |
| No drains in Grade A/B; sealed drains elsewhere | Source: Annex 1 4.9 · Schedule M Part II 8.6 | Drain monitoring and treatment from outside the clean area, with a log. |
| Entry only through airlocks | Source: Schedule M Part II 1.1 and 8.7–8.8 · Annex 1 4.12 | Monitoring at change rooms and material airlocks — the points pests use to move inward. |
| Premises that keep out insects and animals | Source: Schedule M Part I 12.2.9 · EU-GMP Chapter 3.4 | Survey of service floors, ceiling voids and penetrations, with photos. |
How we protect each part of the plant
Different zones carry different risks. The method changes with the zone — the documentation does not.
Grade A/B
Risk: Any intrusion is a critical deviation.
What we do: No chemicals and no devices that cannot be disinfected. Inspection only — control happens outside.
Grade C/D and clean corridors
Risk: Drain flies and ants.
What we do: Sealed, cleanable monitoring devices compatible with your disinfectant, plus drain checks.
Change rooms and material airlocks
Risk: Insects carried in on people, pallets and cartons.
What we do: Monitoring along the cascade and checks of incoming-material areas.
Service floors and ceiling voids
Risk: Rodents and cockroaches in ducts and cable trays.
What we do: Bait stations and traps in technical areas; gap and penetration sealing.
Roof and AHU intakes
Risk: Birds roosting near air intakes.
What we do: Mesh, spikes and gap sealing, documented with photos.
Warehouse and dispatch
Risk: Rodents and birds at the docks.
What we do: Numbered rodent stations and dock-door proofing.
The documents you hand the inspector
Pest-control SOP and risk assessment
Written for your site, version-controlled, ready to file in your QA system.
Numbered device map
Every rodent station, glue board and insect light trap marked on your site plan.
Service visit reports
Signed after every visit: what was checked, what was found, what was done.
Monthly trend analysis
Pest activity by zone and by month, so QA sees problems before an inspector does.
Approved chemical list
CIB&RC-registered products only, with labels and safety data sheets.
Licence and training records
Operator licence and technician training records for your vendor-qualification file.
Corrective-action log
Each finding root-caused and closed with evidence, ready for your CAPA system.
From first visit to inspection-ready
Free audit-readiness inspection
We walk the plant with your QA or engineering lead — warehouses, AHU spaces, docks and perimeter.
Gap summary
What an inspector would likely find today, mapped to Schedule M, USFDA or WHO-GMP, with photos.
Programme and SOP
Device map, service frequency and approved chemicals, agreed with QA before work starts.
Monthly service and trend reports
A report after every visit and a trend analysis every month, by zone and by pest.
Quarterly review and CAPA closure
Findings reviewed with QA and closed with evidence, ready for your next inspection.
The first inspection is free and carries no obligation.
Book a free sterile-site inspection.
We review your building, drains and airlocks with QA and show where pests could reach the clean area — before an inspector does.
98114 90080Common questions from sterile and ophthalmic plants
Which of your devices go inside Grade C/D, and how do we disinfect them?
Only sealed monitoring devices that can be wiped with your own disinfectant, placed where QA approves. Nothing goes into Grade A/B. Bait and chemicals stay in Grade D, technical areas and outside.
Will you be qualified as a service provider under our Annex 1 contamination control strategy?
Yes. We provide the SOP, method statements, chemical list, technician training records and a change-control trail, and we accept audits by your QA team.
How do you deal with drain flies without opening a contamination route?
Drains are monitored and treated from outside the clean area wherever possible, and drain traps are checked on each visit. Findings go into the trend report so engineering can fix the drain, not just treat it.
Do you fumigate cleanrooms?
No. The fumigation mentioned in Schedule M Part II is for microbial control and belongs to your own sanitisation programme. Pest control in classified areas is monitoring and exclusion only.
What happens if an insect is found inside a classified area?
We help QA investigate: identify the insect, trace the route — drain, airlock, incoming material or a gap in the building — close it, and document the corrective action for your deviation report.
Other pharmaceutical segments
Different products, different pest risks. See the programme for each.
API / Bulk Drugs
Drum yards, open process bays and solvent areas — bird-proofing and ICH Q7-mapped SOPs.
See the programmeTablets & Capsules
Beetles in excipient stores, birds in AHU rooms — and no sprays near compression or coating.
See the programmeAyurvedic, Herbal & Nutraceuticals
Beetles and moths in raw-herb stores, approved fumigation, Schedule T and FSSAI records.
See the programmeWarehousing & Distribution
Docks, racking, cold rooms and vehicles — GDP-ready records for C&F agents and distributors.
See the programmeGet your sterile and ophthalmic plant audit-ready.
We review your building, drains and airlocks with QA and show where pests could reach the clean area — before an inspector does.